Dual Provider Switch NID

 

 

Product Description:
The Switch NID from Suttle allows two providers' service to be controlled at the premise distribution device through a simple, customer-operable switch. The Switch NID eliminates the need for service truck rolls and jack re-wiring when the service is changed by the home owner. Intended for Star Wired/Home Run/Daisy Chain with a distribution device applications.

 

 

 

Application:


The Switch NID is designed for a competitive service provider to distribute voice service through a home's existing wiring. The Switch NID may either be terminated at the premise's distribution device or at the incumbent's network interface device. The incumbent service provider's incoming wires and the premise wires are terminated to the screw terminals (Figure 1). All jacks in the premise will be controlled through this Switch NID.

 

The Switch NID may be integrated with an alarm dialing device (Figure 2).

 

 

 

Product Features:

  • Customer-operable switches for line one and line two.
  • Wire it once - no rewiring required if service turned back to incumbent.
  • Weather Resistant Enclosure.
  • Customizable for your name/logo to reinforce your brand.

 

 

 

Wiring Instructions:

  1. Mount the Dual Provider Switch NID near the incumbent network interface device (or distribution device). The Dual Provider Switch NID should be mounted in a location that allows for easy access. The device should be mounted away from water sources such as sprinklers, downspouts, etc.

    Vertical Surface Mounting: This device may be mounted on any flat vertical surface using the external mounting features. Mounting the unit on a flat surface will prevent the unit from warping, which could allow water to penetrate into the interior. Use flat washers as shims to help keep the unit level and vertical on uneven surfaces. Mount the unit to the wall using two mounting screws.

    Conduit Mounting: This device can be mounted on vertical conduit by wrapping metal straps around the external mounting features. Mount the unit in a vertically level position to prevent water from entering.

  2. Open the cover. A wire entry grommet is located at the bottom of the unit for wiring. Since the grommet is designed to provide a watertight seal around the incoming wires, special care must be taken to create the correct type of hole in the grommet. If the hole is made too large, water, insects, dirt or other foreign objects may enter the unit. Remove the grommet from the base. Using a pencil point, a pair of needle nose pliers or a similar long thin object, punch a small hole in the center of the grommet - do not use a knife or cutters. A knife may cut all the way through the grommet and cutters may make a hole that is too large for a tight fit.

  3. It is highly recommended that you disconnect the incumbent telephone service line at the demarcation point before proceeding. Bring a cable from the incumbent's NID and the premise distribution cables up to the device allowing 8" to dress wires. If an alarm device is present, a cable from the EMTA and a cable from the alarm device must be brought to the device as well (see instruction step 7). Thread the incoming cables through the hole in the grommet and return the grommet to its place in the housing. A cable tie holder is located just above the entry grommet to provide strain relief for the incoming cables. Put a cable tie through the cable tie holder and tighten it around the cables so they do not slip. Do not crush the cables.

  4. Strip the outer jacket from the cable exposing the insulated conductors. Strip approximately ½ inch (12.7 mm) of insulation off each of the conductors. Back the screw terminal out 1 turn. Wrap the bare wire in a clockwise direction around the screw terminal between the washers. Tighten the screw and then cut off any excess wire.

  5. Terminate the tip and ring wires from the incumbent's cable to the screw terminals under the switch in the "A" position (see fig.1). The wires for line one are typically red and green (occasionally blue and white/blue). The wires for line two are typically yellow and black (occasionally orange and white/orange). Terminate the tip and ring wires from the premise distribution cables to the screw terminals in the bottom of the enclosure (see fig.1).

  6. Plug the incumbent telephone service line back in at the demarcation point (if there is an alarm device present, first proceed to step 7) and set the switch to the proper position (Company B for EMTA, and Company A for incumbent). Check to see that the telephone is working properly.

  7. If an alarm device or RJ31x jack is present, a dedicated cable needs to be run from the phone outlet that the EMTA will be plugged into. This outlet may no longer be used for a telephone. Terminate the tip and ring wires from this cable to the screw terminals under the switch in the "B" position (see fig.2). An alarm device may be plugged directly into the RJ31X jack on the 650Sx-SB product version. This product feature is intended for indoor use only. If installed outdoors, the manufacturer accepts no liability for alarm failure. If this device needs to be installed outdoors and has an alarm device wired to it, use the standard product version and follow these instructions. Remove the spade terminals from the premise distribution screw terminals (on the line intended for the alarm device) and move them to the alarm device screw terminals. From an RJ31X jack installed inside the premise, run a cable out to the device and terminate the RJ31X jack's inner tip and ring wires (conductors 5 and 4) to the alarm device screw terminals. Terminate the RJ31X jack's outer tip and ring wires (conductors 8 and 1) to the premise distribution screw terminals (see fig.2).

 

 

 

Product Specifications:


Terminals:
Contact Pressure:
Contact Resistance:
Insulation Resistance:
Current/Voltage:
Listed

-
-
-
-
-
-
Binding Screws
100 grams minimum
5 milliohms maximum
500 mega ohms minimum
140 VDC @ 2 amps
cULus (pending)

 

 

 

Dimensions:

 

 

 

Ordering Information:


Part Number
650S1

650S2

650S1-SB

650S2-SB


- -

- -

- -

- -
Description
Single line (indoor/outdoor), screw terminals, grease filled switches
Dual line (indoor/outdoor), screw terminals, grease filled switches
Single line w/ RJ31X interface (indoor only), screw terminals, grease filled switches
Dual line w/ RJ31X interface (indoor only), screw terminals, grease filled switches

 

 

 

Literature:

Switch NID Datasheet
Switch NID Installation Instructions
Dual Provider Switch Products Line Card
   
 
 

Specifications subject to change without notice. Copyright 2005. Original: 6/05